Scintillation Detectors and probes
-
The scintillation crystals is matched to PMT and then the whole assembly is encapsulated hermetically in the aluminum or stainless steel housing, and the preamplifer circuit and output connect could be installed if it is required. The scintillation crystals could be NaI(Tl), CsI(Tl), LYSO(Ce), BGO, LaBr3(Ce) or CeBr3 ect., and PMT could be Hamamatsu, ET or other suppliers. Besides some standard design scintillation detectors and probes modules, Hangzhou Shalom EO will provide the customized detectors upon your request.
-
The NaI(Tl) scintillation detector is a hermetically sealed assembly, it consists a high resolution diameter 50mm x 50mm length NaI(Tl) crystal, a diameter 2 inch photomultiplier tube, an internal magnetic light shield, an aluminum housing and a 14 pin connector.
-
The NaI(Tl) scintillation detector is a hermetically sealed assembly, it consists a high resolution diameter 75mm x 75mm length NaI(Tl) crystal, a diameter 3 inch photomultiplier tube, an internal magnetic light shield, an aluminum housing and a 14 pin connector.
-
NaI(Tl) detector is a high efficiency scintillation detector consisting of a NaI(Tl) crystal in an Aluminum housing, a photomultiplier tube, an internal magnetic/light shield, a high-voltage power supply(HVPS), a voltage divider and preamplifier circuit board, it can directly output the negative pulse signal. NaI(Tl) detectors have a proven record of long term reliability and stability. Typical energy resolutions are ≤8%fwhm at 662keV.
-
NaI(Tl) detector is a high efficiency scintillation detector consisting of a NaI(Tl) crystal in an Aluminum housing, a photomultiplier tube, an internal magnetic/light shield, a high-voltage power supply(HVPS), a voltage divider and preamplifier circuit board, it can directly output the negative pulse signal. NaI(Tl) detectors have a proven record of long term reliability and stability. Typical energy resolutions are ≤8%fwhm at 662keV.
-
NaI(Tl) detector is a high efficiency scintillation detector consisting of a NaI(Tl) crystal in an Aluminum housing, a photomultiplier tube, an internal magnetic/light shield, a high-voltage power supply(HVPS), a voltage divider and preamplifier circuit board, it can directly output the negative pulse signal. NaI(Tl) detectors have a proven record of long term reliability and stability. Typical energy resolutions are ≤9%fwhm at 662keV.
-
NaI(Tl) detector is a high efficiency scintillation detector consisting of a beryllium entrance window NaI(Tl) scintillator, a photomultiplier tube, an internal magnetic/light shield, a voltage divider and preamplifier circuit board, it can directly output the negative pulse signal. NaI(Tl) detectors have a proven record of long term reliability and stability. Typical energy resolutions are ≤60.0%fwhm at 5.9keV(Fe-55).